MAX30102 Pulse Oximeter Heart Rate Sensor Module
MAX30102 Pulse Oximeter Heart Rate Sensor Module The MAX30102 Pulse Oximeter Heart-Rate Sensor Module I2C Interface provides a complete system solution to ease the design-in process for mobile and wearable devices. The MAX30102 operates on a single 1.8V power supply and a separate 5.0V power supply for the internal LEDs. Communication is through a standard I2C-compatible interface. The module can be shut down through software with zero standby current, allowing the power rails to remain powered at all times. The heart rate oximetry module made with the MAX30102 is an upgraded version of the MAX30100 that can be used to measure heart rate oximetry on the wrist. It can be applied to smart wear fields such as sports watches. MAX30102 is an integrated pulse oximeter and heart-rate monitor sensor solution. It’s an optical sensor that derives its readings from emitting two wavelengths of light from two LEDs – a red and an infrared one – then measuring the absorbance of pulsing blood through a photodetector. This particular LED colour combination is optimized for reading the data through the tip of one’s finger. It is fully configurable through software registers and the digital output data is stored in a 16-deep FIFO within the device. It has an I2C digital interface to communicate with a host microcontroller. The pulse oximetry subsystem in MAX30102 consists of ambient light cancellation (ALC), 16-bit sigma delta ADC, and a proprietary discrete-time filter. It has an ultra-low-power operation which makes it ideal for battery-operated systems. MAX30100 operates on a supply in the range of 1.8 to 3.3V. It can be used in wearable devices, fitness assistant devices, medical monitoring devices, etc. The MAX30102 operates from 1.8V and 3.3V power supplies and can be powered down through software with negligible standby current, permitting the power supply to remain connected at all times. read our blog on eye blinking sensor, which provides information about the working principle of an eye blink sensing system. Note: For this sensor, you have to pull up SCL & SDA Pin( You have to connect a 10Kohm resistor between SCL & 5V And Same as SDA to 5V) Applications: Fitness Assistant Devices Medical Monitoring Devices Wearable Devices Package Includes: 1 x MAX30102 Pulse Oximeter Heart Rate Sensor Module Specifications: Voltage 1.8 - 3.3v Current 0.7 µA Length 5.6m Width 2.8mm Height 1.2mm Weight 2gm
- It is an integrated pulse oximetry and heart rate monitor sensor
- Integrated Cover Glass for Optimal, Robust Performance
- Integrated LEDs, Photo Sensor, and High-Performance Analog Front -End
- Non-chest based heart-rate/SpO2 detection
- I2C interface plus INT pin
- Ultra-Low-Power Operation Increases Battery Life for Wearable Devices
- Programmable Sample Rate and LED Current for Power Savings
- High SNR Provides Robust Motion Artifact Resilience
- Integrated Ambient Light Cancellation
- High Sample Rate Capability
- Fast Data Output Capability
- 1 x MAX30102 Pulse Oximeter Heart Rate Sensor Module
- Voltage 1.8 - 3.3v
- Current 0.7 \u00b5A
- Length 5.6m
- Width 2.8mm
- Height 1.2mm
- Weight 2gm