7Semi BME688 Environmental Sensor Nano Breakout with 2.54mm Pitch Header
Delivery & Pickup Options
Pick up today from our store.
Estimated delivery: 2-5 business days
7Semi BME688 Environmental Sensor Nano Breakout with 2.54mm Pitch Header The 7Semi BME688 Environmental Sensor Nano Breakout with 2.54mm Pitch Header is a versatile and high-precision environmental sensor designed for modern monitoring applications. Built around Bosch’s advanced BME688, it accurately tracks temperature, humidity, air pressure, and gas levels, helping you gain meaningful insights into environmental conditions. Its compact nano form factor and I2C interface make integration simple with Arduino, Raspberry Pi, and other development boards. Whether you’re building a smart home system, an industrial monitoring setup, or an environmental research project, this environmental monitoring sensor delivers dependable performance in a user-friendly design. Features: AI-Enhanced Gas Sensing: Identifies dangerous gasses with exceptional accuracy. Comprehensive Monitoring: A single sensor measures numerous essential environmental factors. Flexible Interface: I2C connectivity enables seamless interaction with microcontrollers. Compact design: The nano breakout board is ideal for projects with limited space. 3.3V Operating Voltage: Suitable for a wide range of development boards. Gas sensor sensitivity, selectivity, and data rate can all be adjusted to meet your individual application requirements.
- Compact Environmental Sensor breakout powered by Bosch BME688 for reliable multi-parameter sensing
- Measures temperature, humidity, barometric pressure, and gas levels in real time
- Nano-sized design with 2.54mm pitch header for easy breadboard and PCB integration
- I2C interface ensures quick and stable communication with microcontrollers
- Ideal environmental monitoring sensor for smart homes, IoT, industrial, and research projects
- Parameter Specification
- Operating Voltage 3.3V
- Interface I2C
- Pressure Range 300 – 1100 hPa
- Humidity Range 0 – 100 %RH
- Temperature Range -40°C to +85°C
- F1 Score (H₂S Scanning) 0.92
- Standard Scan Speed 10.8 s / scan
- Electric Charge (Standard Scan) 0.18 mAh (≈5 scans/min)
- Response Time (T 33–63%) < 1 s (new sensors)
- Response Time (T 0–63%) 8 s
- Accuracy Tolerance ±3 %RH
- Hysteresis ≤ 1.5 %RH
- RMS Noise 0.12 Pa (equivalent to 1.7 cm)
- Sensitivity Error ±0.25 % (≈ 1 m at 400 m height change)
- Temperature Coefficient Offset ±1.3 Pa/K (≈ ±10.9 cm at 1°C change)